Principle of CO2 ultra short pulse fractional skin pigmentation removal laser beauty machine
CO2 laser system generate a 10,600nm wavelength, which is absorbed by water in the tissue. The laser energy heats up the water until it reaches a boiling point causing the evaporation of the affected tissue. Some heat is absorbed by tissue adjacent to the ablated target area, causing tissue coagulation which induces hemanyasis (the essation of bleeding) as well as thermal stimulation.
Fractional co2 laser For Vaginal Tigenting
It should be viewed as a medical treatment to counter vaginal dryness and the uncomfortable symptoms associated with menopause. This simple in-office procedure will stimulate collagen production and in turn improve the blood supply and moisture levels to the vaginal tissues. is about function and allows menopausal women to reclaim a higher quality of life.
Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…)
Wrinkles (Crow's feet, head lines, Sichuan characters, Decree lines)
Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting
Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.)
Other applications (syringoma, condyloma, seborrheic, etc.)
Viginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)
Display | 12.1 inch LCD real color touch screen |
Light conducting system | 7 jointed arms to conduct light |
Wavelength | 10.6μm |
Tube Type | USA RF Metal tube/ Glass tube (optional) |
Power | 40W |
Mode | Normal / Scan/ Gynecology |
Laser energy | 1-40W / 10-1000mj |
Figure option | Square, Triangle, Round, Rectangle, Line, |
Scan pattern size | 4mm---20mm(2mm) |
Scan mode | Random scan; Sequence scan |
Dot quantity | 25,000 dots |
Spot distance | 0.2-2mm |
Pulse energy | 1mj to 100mj is optional for each dot. |
Times of scanning | 1- 10 times |
Condenser focus | f=50mm |
Spot size | ≤0.2mm at the focus |
Radiation time / Interval time | 0.011s |
Aiming beam | 635nm infrared ray |
Power supply | 110/230V士10%, 60/50HZ |
Principle of CO2 ultra short pulse fractional skin pigmentation removal laser beauty machine
CO2 laser system generate a 10,600nm wavelength, which is absorbed by water in the tissue. The laser energy heats up the water until it reaches a boiling point causing the evaporation of the affected tissue. Some heat is absorbed by tissue adjacent to the ablated target area, causing tissue coagulation which induces hemanyasis (the essation of bleeding) as well as thermal stimulation.
Fractional co2 laser For Vaginal Tigenting
It should be viewed as a medical treatment to counter vaginal dryness and the uncomfortable symptoms associated with menopause. This simple in-office procedure will stimulate collagen production and in turn improve the blood supply and moisture levels to the vaginal tissues. is about function and allows menopausal women to reclaim a higher quality of life.
Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…)
Wrinkles (Crow's feet, head lines, Sichuan characters, Decree lines)
Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting
Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.)
Other applications (syringoma, condyloma, seborrheic, etc.)
Viginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)
Display | 12.1 inch LCD real color touch screen |
Light conducting system | 7 jointed arms to conduct light |
Wavelength | 10.6μm |
Tube Type | USA RF Metal tube/ Glass tube (optional) |
Power | 40W |
Mode | Normal / Scan/ Gynecology |
Laser energy | 1-40W / 10-1000mj |
Figure option | Square, Triangle, Round, Rectangle, Line, |
Scan pattern size | 4mm---20mm(2mm) |
Scan mode | Random scan; Sequence scan |
Dot quantity | 25,000 dots |
Spot distance | 0.2-2mm |
Pulse energy | 1mj to 100mj is optional for each dot. |
Times of scanning | 1- 10 times |
Condenser focus | f=50mm |
Spot size | ≤0.2mm at the focus |
Radiation time / Interval time | 0.011s |
Aiming beam | 635nm infrared ray |
Power supply | 110/230V士10%, 60/50HZ |